Heat insulated, dry, overground fire hydrant JAFAR 8003 (DN100)

Model: JAFAR 8003
Rating:
0% of 0 votes 0/5 based on 0 reviews!

Warm dry overground hydrant JAFAR 8003 (DN100)

*Product description is based on information provided by the manufacturer about the product. The description and photos are informative, operational changes are possible. In accordance with certain modifications from the manufacturer changes may be made in the description of the product or its parameters.

Advantages:

  • Double shutter system;
  • Additional protection in case of damage;
  • One-piece cast upper housing;
  • The possibility to rotate the housing 0° to 360°.

Technical parameters and Compliant with:

  • In conformity with EN 14384:2005 type C and LVS187;
  • Designed for clean water according to EN 1074-6:2004;
  • Connections of flanges according to EN 1092-2:1999;
  • Flange A 110 according to DIN 14319;
  • Flange B 75 according to DIN 14318;
  • Two access points DN80, height 0,76 m;
  • The control key according to PN-89/M-74088;
  • Diameter/Operating pressure: DN100/PN16;
  • Operating temperature range till +50°C

Properties of construction:

The hydrant body is made of steel pipe (stainless steel pipe - on request);

The hydrant is insulated with polyurethane foam, the insulation coating is made of PVC, the height is 90 cm, waterproof, sealed with a rubber seal;

Stainless steel bar with polished thread for tight connection;

Stainless steel shaft;

Shaft seal type - rubber sealing ring,

Automatic water drainage,

The time of water draining - according to the norm;

The shutters - cap type and ball type; completely vulcanized by EPDM;

Start of opening – after 3 turns; Full opening - after 8 revolutions;

MOT 80 Nm; mST 250Nm;

You can change internal elements under pressure;

External and internal materials are resistant to corrosion;

Resistant against the effects of disinfectants (NaOCI solution);

Coloring: UV resistant, epoxy paint RAL3000 250 mkm;

Used for:

In firefighting and water supply systems, to regulate water supply;

Можно проWeightти ремонт гидранта sверху без копательных работ;

CE certificate;

Certificate CNBOP (Jozefow);

Hygiene certificate (Polish Hygiene Institute (PZH));

Installation:

Installation type - in vertical position on a horizontal water pipe.

  • Other colors are available in RAL catalog.

(Due to the constant company development, we reserve the right to make changes and modifications in goods produced by out company).

Related services categories

Comments RSS feed Comments

Add New Comment

In your cart